info@kps.com.vn
+84 903 709 019
The Simplex 4098-XAD is an addressable duct smoke detector (IGF) that uses air-sampling technology combined with a TrueAlarm photoelectric smoke sensor. It is designed to detect smoke in HVAC ducts or hard-to-access areas. The unit features environmental compensation, airflow monitoring, replaceable dust filters, and remote test/maintenance capability, ensuring high reliability and convenient servicing.
Detects smoke in air ducts (not a replacement for open-area detectors).
Airflow supervision: alerts when abnormal airflow is detected.
Aspirator fan with 10 programmable speeds, LED bar-graph display.
Replaceable air filter (recommended replacement every 12 months).
Remote testing functions: smoke test, magnet test, or via remote test station 2098-9806.
Status LED indicators (on housing or via remote).
Compatible with external relay (4098-9843) for auxiliary equipment control.
Dedicated 24VDC power supply, easy integration with fire alarm systems.
4098-XAD-110: 1 detector + 1 sampling tube set.
4098-XAD-210: 2 detectors + 2 sampling tube sets (for ducts wider than 90 in / 2.3 m).
4098-XAD-100: 1-port version for open-area applications.
4098-XAD-200: 2-port version for open-area applications.
Sampling tubes (27", 54", 90").
Flexible tubing (25 ft or 50 ft).
Water trap to prevent moisture/condensation.
Remote LED (2098-9808) and Remote Test Station (2098-9806).
Relay 4098-9843 + EOL resistor 4081-9008.
Replacement filter 02-FL53.
Power supply: 18–30 VDC, initial inrush current 680 mA.
Fan current: 110–300 mA depending on speed.
Supervision relay output: up to 15 relays, max distance 152 m.
Rigid tubing: up to 25 m (duct applications) or 50 m (open-area applications).
Flexible tubing: up to 15 m.
Air velocity: 0–4000 ft/min (0–1220 m/min).
Smoke sensitivity range:
Duct: 0.5–1.0 %/ft
Open area: 1.5–3.0 %/ft
Operating temperature: 0–50 °C.
Humidity: 10–95% RH, non-condensing.
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4007ES addressable fire alarm control panel – powerful, flexible solution for small to medium sized projects, supporting network connectivity and system integration.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Simplex 4017ES addressable fire alarm control panel supports up to 250 IDNet2 points, integrated IDNAC 4A power source, Class A/X digital audio, compatible with TrueAlarm sensors.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Điện thoại cứu hỏa Simplex liên lạc hai chiều giữa trung tâm và lính cứu hỏa, lắp âm/nổi, chống phá hoại, đạt chuẩn UL, FM
View detail
The Simplex 2008FS Fire Alarm Control Unit (FACU) provides flexible initiating circuit supervision and extensive programmable control for areas requiring one to eight initiating zones.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
View detail
2010 © Bản quyền thuộc KPS
Online: 6 | Visitors Counter: 14267963
About | Recruitment | News | Contact Us