info@kps.com.vn
+84 903 709 019
The Fire Alarm Ethernet Switch is a purpose-built device designed specifically for Fire Alarm LAN (Local Area Network) applications, connecting the TrueSite Workstation Server with Remote Clients.
It ensures earth fault supervision on each Ethernet port.
Certified to UL 864, ULC S527, CSFM Listed, and FM Approved.
Dedicated Fire Alarm LAN
Provides exclusive Ethernet connections between the TrueSite Workstation server and Remote Clients through Fire Alarm Ethernet Switches.
Multiple connection options
8 wired Ethernet ports (RJ-45) — Model 4190-6050.
4 wired Ethernet ports + 2 single-mode fiber ports — Model 4190-6054.
4 wired Ethernet ports + 2 multi-mode fiber ports — Model 4190-6055.
Collision domain segmentation
Enables network segmentation to increase resilience and performance of the life safety network.
Earth fault detection
Integrated ground fault detection module on RJ-45 connections.
Fault conditions indicated via:
IDNet Supervised IAM module,
Trouble relay output,
Per-port fault LEDs.
Extended networking
Supports cascading multiple switches to expand connections or extend network distance (via Ethernet or fiber cabling).
Safety compliance
Fire alarm listed versions: UL 864, ULC S527 (Models 4190-6050, 6054, 6055).
Non-listed versions also available for general networking applications (not for fire alarm safety).
Input Voltage: 24 VDC.
Current Draw: 300 mA max.
Trouble Relay: Form C, 0.3 A @125 VAC, 1 A @30 VDC.
Cabling: Cat3/Cat5, 10/100 Mbps.
Fiber: SC connectors (requires 2 fibers Tx/Rx).
Cabinet Size: 343 x 343 x 84 mm, red enclosure, lockable.
Environment: 0–49 °C, up to 90% RH (non-condensing).
Fire Alarm Ethernet Switch (with earth fault supervision, agency listed)
4190-6050: 8 RJ-45 Ethernet ports.
4190-6054: 4 Ethernet ports + 2 single-mode fiber (SC).
4190-6055: 4 Ethernet ports + 2 multi-mode fiber (SC).
Ethernet Switch (non-supervised, non-listed)
4190-6051: 8 RJ-45 Ethernet ports.
4190-6056: 4 Ethernet ports + 2 single-mode fiber.
4190-6057: 4 Ethernet ports + 2 multi-mode fiber.
➡ Requires power adapter:
4190-6052: 120 VAC.
4190-6053: 240 VAC.
4190-6010: Transient Suppressor (mandatory when connecting LAN/WAN unless server and client are in the same room).
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4007ES addressable fire alarm control panel – powerful, flexible solution for small to medium sized projects, supporting network connectivity and system integration.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Simplex 4017ES addressable fire alarm control panel supports up to 250 IDNet2 points, integrated IDNAC 4A power source, Class A/X digital audio, compatible with TrueAlarm sensors.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Điện thoại cứu hỏa Simplex liên lạc hai chiều giữa trung tâm và lính cứu hỏa, lắp âm/nổi, chống phá hoại, đạt chuẩn UL, FM
View detail
The Simplex 2008FS Fire Alarm Control Unit (FACU) provides flexible initiating circuit supervision and extensive programmable control for areas requiring one to eight initiating zones.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
View detail
2010 © Bản quyền thuộc KPS
Online: 36 | Visitors Counter: 14170803
About | Recruitment | News | Contact Us