The Simplex 4098-5610, 5611, 5612, and 5613 heat detectors are designed to detect fire conditions by monitoring fixed temperature thresholds or rate-of-rise temperature increases. They are ideal for areas such as mechanical rooms, kitchens, or dusty environments where smoke detectors may be less effective.
4098-5610: Combination of fixed temperature (135 °F / 57.2 °C) and rate-of-rise detection.
4098-5611: Fixed temperature only, at 135 °F (57.2 °C).
4098-5612: Higher fixed temperature threshold, 200 °F (93.3 °C).
4098-5613: Combination of fixed temperature (200 °F / 93.3 °C) and rate-of-rise detection.
Modern Detection Design:
Does not rely on fusible metal elements or traditional bimetallic mechanisms → provides faster, more accurate response.
Two Detection Methods:
Fixed Temperature: Alarm when the preset temperature threshold is exceeded.
Rate-of-Rise: Alarm when the temperature rises by ≥ 20 °F/min (≥ 11 °C/min), only active above 90 °F (32 °C) → reduces false alarms in cooler spaces.
LED Status Indicator:
Clearly shows normal and alarm conditions for quick inspection.
Flexible Compatibility:
Operates with standard 2-wire or 4-wire IDC circuits, making installation and replacement simple.
Operating Voltage (2-wire): 10.5 – 33 V DC
Rated Voltage (4-wire): 15 – 32 V DC
Standby Current: < 70 µA
Alarm Current: Up to ~64 mA @ 30 V, ~33 mA @ 20 V, ~14.5 mA @ 12 V
Air Velocity Range: 0–2000 ft/min (0–610 m/min)
Operating Temperature: ~0°C – 38°C (32°F – 100.4°F); some references note -9°C – 50°C
Humidity Range: 10–95% RH (non-condensing)
Dimensions: ~124 mm diameter × 48 mm height (with base)
UL Listed – Meets UL Standard 521 – 7th Edition for heat detectors.
ULC Listed (Canada) – Some models certified for Canadian applications.
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4007ES addressable fire alarm control panel – powerful, flexible solution for small to medium sized projects, supporting network connectivity and system integration.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Simplex 4017ES addressable fire alarm control panel supports up to 250 IDNet2 points, integrated IDNAC 4A power source, Class A/X digital audio, compatible with TrueAlarm sensors.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Điện thoại cứu hỏa Simplex liên lạc hai chiều giữa trung tâm và lính cứu hỏa, lắp âm/nổi, chống phá hoại, đạt chuẩn UL, FM
View detail
The Simplex 2008FS Fire Alarm Control Unit (FACU) provides flexible initiating circuit supervision and extensive programmable control for areas requiring one to eight initiating zones.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
View detail
2010 © Bản quyền thuộc KPS
Online: 9 | Visitors Counter: 14240798
About | Recruitment | News | Contact Us