info@kps.com.vn
+84 903 709 019
Product Code: 2008FS
Product Line: Fire Alarm Controller
Brand: Simplex
Origin: USA
The Simplex 2008FS Fire Alarm Control Unit provides flexible initiating circuit monitoring and extended programmable control capability for applications requiring one to eight initiating zones.
Central fire alarm panel designed for easy operation and configuration.
2-line LCD display with dedicated LEDs for clear system status indication.
Programming available directly on the panel via keypad or through PC software via USB port.
Supports upload/download of configurations, software updates, and event history extraction.
Provides 8 Class B IDC circuits (or 4 Class A), compatible with detectors and manual stations, including TrueAlarm™ detectors.
Includes 2 Class A/B NAC circuits, each rated at 1.5 A, supporting SmartSync™ two-wire control and synchronized strobe mode.
Built-in 3 A power supply at 24 VDC with automatic input voltage selection (120 VAC/60 Hz or 240 VAC/50 Hz).
Temperature-compensated battery charger supports batteries up to 7 Ah (in cabinet) or 25 Ah (external).
Non-volatile memory stores alarm, trouble, supervisory, and user logs.
WALKTEST feature (audible or silent) for system testing.
Includes 4 programmable auxiliary relays, active status reminder, and expansion options for City Circuit module or Remote LCD Annunciator.
UL 864 listed, meeting international fire protection safety standards.
Input voltage: 120 VAC, 60 Hz or 240 VAC, 50 Hz (auto selection)
Input current: 4 A max @ 120 VAC; 3 A max @ 240 VAC
Output: 24 VDC, up to 3 A (alarm condition)
Battery charger: Temperature-compensated, supports up to 25 Ah batteries
Standby current: 226 mA (with 4 Class A IDC fully loaded)
IDC (Initiating Device Circuits):
8 Class B or 4 Class A
Up to 30 detectors per circuit
EOL resistor: 3.3 kΩ (4.7 kΩ option for retrofit)
NAC (Notification Appliance Circuits):
2 Class A/B circuits
1.5 A each @ 24 VDC
Supports SmartSync™
EOL resistor: 10 kΩ (other values allowed in retrofit)
NAC supervision current: max 9 mA
NAC alarm current: max 60 mA
Auxiliary Power: 24 VDC, up to 500 mA (combined)
Relays:
4 total (1 fixed Trouble relay, 3 programmable)
Contact rating: 2 A @ 30 VDC or 0.5 A @ 30 VAC, selectable NO/NC
Annunciators:
Supports up to 4 remote LCD annunciators
Wiring: 18 AWG twisted pair, max distance 1,200 m
Requires 100 Ω end-of-line resistor
Outdoor installation requires surge protection
Environmental:
Operating temperature: 0°C to 49°C (32°F to 120°F)
Humidity: ≤ 93% RH non-condensing @ 32°C
4098-5601: Photoelectric Smoke Detector
4098-5602: Photo/Heat Detector
4098-5610: Heat Detector, rate-of-rise & fixed, 135°F (57°C)
4098-5611: Heat Detector, fixed, 135°F (57°C)
4098-5612: Heat Detector, fixed, 200°F (93°C)
4098-5613: Heat Detector, rate-of-rise & fixed, 200°F (93°C)
4098-9688: 2-wire Duct Smoke Detector with housing & relay
4098-9686: 4-wire Duct Smoke Detector with housing & relay
Sampling tubes:
4098-9854: 305 mm (12 in.) duct
4098-9855: 330–584 mm (13–23 in.) duct
4098-9856: 610–1,168 mm (24–46 in.) duct
4098-9857: 1,168–1,803 mm (46–71 in.) duct
4098-9858: 1,803–2,413 mm (71–95 in.) duct
4 in. / 5 in. standard bases: 4098-5261, 4098-5207
6 in. adaptor for 5 in. base: 4098-9799
5 in. 2-wire relay base: 4098-5680
5 in. 4-wire relay base: 4098-5682
4009 Series NAC Extender: Provides additional NAC outputs, includes power supply & charger. Supports up to 4 extenders per NAC (Datasheet: S4009-0002).
4009-9201: IDNet NAC Extender, 4 Class B NACs, 8 A PSU, 120 VAC, UL Listed, seismic tested
4009-9301: IDNet NAC Extender, 4 Class B NACs, 8 A PSU, 240 VAC, UL Listed
4009-9807: NAC Option Card, adds 4 conventional NACs (max 1 card)
4009-9808: Dual Class A Adapter (for 2 NAC outputs, max 4 adapters)
2975-9802: Semi-Flush Trim Kit, red
2008-9101 (FACU): 130 mA supervisory / 160 mA + 60 mA per IDC in alarm
2004-9909 (City Circuit Module): 30 mA supervisory / 60 mA alarm
2606-9101 (LCD Annunciator): 40 mA supervisory / 48 mA alarm
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4007ES addressable fire alarm control panel – powerful, flexible solution for small to medium sized projects, supporting network connectivity and system integration.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Simplex 4017ES addressable fire alarm control panel supports up to 250 IDNet2 points, integrated IDNAC 4A power source, Class A/X digital audio, compatible with TrueAlarm sensors.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Điện thoại cứu hỏa Simplex liên lạc hai chiều giữa trung tâm và lính cứu hỏa, lắp âm/nổi, chống phá hoại, đạt chuẩn UL, FM
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
View detail
Simplex IDNet Addressable Modules add addressing, monitoring & control to common devices, enhancing safety and system integration.
View detail
2010 © Bản quyền thuộc KPS
Online: 21 | Visitors Counter: 14254717