The 49VO Series is a visible-only strobe notification appliance (no audible output), ceiling-mounted, individually addressable, and directly powered/controlled via the Simplex IDNAC SLC (Signaling Line Circuit). The appliance receives power, supervision, and control commands all through the same two-wire SLC connection.
Multi-Candela Xenon Strobe
Selectable light intensity levels: 15, 30, 75, 110, 135, 185 cd, synchronized at 1 Hz flash rate.
Addressable Smart Operation
Each unit has its own unique address and is fully supervised over the IDNAC SLC—no separate wiring needed.
Efficient 29 VDC Regulated Power
Operates from a regulated 29 VDC supply, even during battery backup, reducing current draw and supporting longer wiring runs.
T-Tap Support for Class B Circuits
Allows T-tapping, reducing wiring and installation time. Class A requires in/out wiring.
Self-Test and Magnet Test
Self-Test: Device checks strobe functionality and reports status back to the control panel.
Magnet Test: Device LED flashes to identify address; strobe may activate to confirm operation.
LED Supervision & Device Reporting
Status LED blinks during polling or when under test; the fire panel can view device ID, label, type, and candela setting.
Certified & ADA Compliant
Meets UL 1971, ULC S526, FM, and ADA accessibility requirements.
Durable & Flexible Design
Flame-retardant, impact-resistant plastic housing in red or white, with easily replaceable covers labeled “FIRE,” “ALERT,” “FEU,” bilingual, Simplex logo, or blank. Covers can be swapped without disturbing wiring.
Easy Installation
Mounts to standard 4-inch square electrical boxes or single-gang boxes with adapter. Terminals accept 18–12 AWG wiring.
Operation & Features
Operating Voltage: 23 – 30 VDC (standard); legacy models support 17–31 VDC
Addressing: Individually addressable, supervised, controlled via IDNAC SLC
Flash Rate: 1 Hz synchronized
Candela Settings:
Standard models: 15, 30, 75, 110 cd
High-candela models: 110, 135, 185 cd
Self-Test & Magnet Test
Self-Test: Verifies strobe flash and reports back to panel
Magnet Test: LED flashes for address ID; strobe may flash for confirmation
Environmental Ratings
Operating Temperature: 0 °C to 49 °C (indoor standard models); –40 °C with high-candela models
Humidity: up to 93% non-condensing, or 95% at 60 °C
Compliance: UL 1971, ULC S526, FM, ADA
1. Appliances (with cover unless noted)
| SKU | Cover Color | Wording | Lens |
|---|---|---|---|
| 49VO-WRF / -BA | Red | FIRE | Clear |
| 49VO-WWF / -BA | White | FIRE | Clear |
| 49VO-WRA / -BA | Red | ALERT | Clear |
| 49VO-WWA / -BA | White | ALERT | Clear |
| 49VO-WRQ | Red | FEU | Clear |
| 49VO-WWQ | White | FEU | Clear |
| 49VO-WRS / -BA | Red | Simplex logo only | Clear |
| 49VO-WWS / -BA | White | Simplex logo only | Clear |
| 49VO-APPLW / -BA | – | – | Requires separate cover & mounting plate |
Dimensions with cover: 130 (H) × 127 (W) × 67 (D) mm
2. Mounting Plates (required for APPLW models)
| Model | Color | Notes |
|---|---|---|
| 49MP-AVVOWR | Red | Required for APPLW(-BA) models |
| 49MP-AVVOWW | White | Required for APPLW(-BA) models |
3. Separate Covers (for APPLW models)
| Model | Color | Wording |
|---|---|---|
| 49VOC-WRFIRE | Red | FIRE |
| 49VOC-WWFIRE | White | FIRE |
| 49VOC-WRALT | Red | ALERT |
| 49VOC-WWALT | White | ALERT |
| 49VOC-WRFEU | Red | FEU |
| 49VOC-WWFEU | White | FEU |
| 49VOC-WRBLNG | Red | FEU/FIRE |
| 49VOC-WWBLNG | White | FEU/FIRE |
| 49VOC-WRS | Red | Simplex logo |
| 49VOC-WWS | White | Simplex logo |
4. Mounting Accessories
| Model | Color | Description | Dimensions |
|---|---|---|---|
| 4905-9937 | Red | Surface mount skirt | 136 × 133 × 41 mm (total depth with strobe: 111 mm) |
| 4905-9940 | White | Surface mount skirt | 136 × 133 × 41 mm |
| 4905-9931 | Red | Adapter plate for 2975-9145 box (horizontal/vertical) | 211 × 146 × 1.5 mm |
| 2975-9145 | Red | Mounting box (requires 4905-9931) | 200 × 130 × 70 mm |
| 4905-9961 | Red | Wire guard with mounting plate | 154 × 154 × 79 mm |
4100ES with EPS+/EPS Supply (DS: S4100-0100)
4009 IDNAC Repeater (DS: S4009-0004)
4007ES with IDNAC (DS: S4007-0002)
4010ES with ESS Power Supply (DS: S4010-0011)
IDNAC SLC Output: 29 VDC regulated, allows up to 6 VDC line drop (minimum 23 VDC at device).
| Specification | Rating |
|---|---|
| Operating Voltage | 23–31 VDC (special: 17 VDC legacy systems) |
| Supervisory Current | 0.8 mA (1 unit load) |
| Max per SLC | 127 devices / 139 unit loads |
RMS Current by Candela Setting (@ 23 VDC, with 6 V drop):
| Candela | 15 | 30 | 75 | 110 | 135 | 185 |
|---|---|---|---|---|---|---|
| Current (mA) | 47 | 57 | 100 | 132 | 160 | 208 |
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4007ES addressable fire alarm control panel – powerful, flexible solution for small to medium sized projects, supporting network connectivity and system integration.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Simplex 4017ES addressable fire alarm control panel supports up to 250 IDNet2 points, integrated IDNAC 4A power source, Class A/X digital audio, compatible with TrueAlarm sensors.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Điện thoại cứu hỏa Simplex liên lạc hai chiều giữa trung tâm và lính cứu hỏa, lắp âm/nổi, chống phá hoại, đạt chuẩn UL, FM
View detail
The Simplex 2008FS Fire Alarm Control Unit (FACU) provides flexible initiating circuit supervision and extensive programmable control for areas requiring one to eight initiating zones.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
View detail
2010 © Bản quyền thuộc KPS
Online: 5 | Visitors Counter: 14278633
About | Recruitment | News | Contact Us