info@kps.com.vn
+84 903 709 019
The 4090-9121 Security Monitor IAM is an individual addressable module (IAM) designed to monitor security devices such as door/window magnetic contacts or other dry-contact devices within a fire alarm and security monitoring system. It is compatible with Simplex/Autocall fire alarm control panels 4100ES, 4100U, and 4010ES via the IDNet communication line.
The module can distinguish different monitored contact states: Open, Normal, Abnormal, and Short.
For use with Simplex® 4100ES, 4100U, and 4010ES fire alarm control panels with IDNet™ communications.
IDNet communication provides both data and power over a single pair of wires.
Monitors a Class B circuit of N.C. (normally closed) or N.O. (normally open) dry contacts.
Monitored states: Open, Normal, Abnormal, Short.
Abnormal condition occurs when supervisory current changes by ±50%.
Maximum distance between IAM and monitored contact: 152 m (500 ft).
Sealed design reduces dust; fits in a standard single-gang electrical box.
Flashing LED indicates communication; optional trim plate allows LED viewing after installation.
UL listed to UL 1076 Security standard.
Each IAM 4090-9121 can monitor up to 5 devices (e.g., door/window magnetic switches or other security contacts).
Armed mode (typically after-hours): Open, short, or abnormal conditions trigger a Priority 2 Alarm at the fire alarm control panel.
Disarmed mode (typically during business hours): Abnormal conditions are reported as events or troubles, depending on configuration.
Communication: IDNet (4100ES, 4100U, 4010ES), occupies 1 address.
Power: Supplied directly from IDNet SLC, consumes 2 unit loads.
IDNet channel capacity:
Up to 32 modules per 64-point channel
Up to 63 modules per 127-point channel
Up to 125 modules per 250-point channel
Monitored contacts:
Up to 5 N.C. contacts wired in series, or
Up to 5 N.O. contacts wired in parallel
Requires appropriate resistor harness (per N.O./N.C. type).
Wiring connections: Screw terminals, 18–14 AWG (0.82–2.08 mm²).
Wiring distance:
IAM ↔ device: 152 m (500 ft)
IAM ↔ FACP: 762 m (2500 ft)
Total SLC wiring (including T-Taps): 3048 m (10,000 ft)
Dimensions: 40 × 44 × 32 mm (1-9/16” × 1-3/4” × 1-1/4”)
Housing: Black thermoplastic
Operating Environment:
Temperature: 0 – 49 °C (32 – 120 °F), indoor use only
Humidity: ≤ 93% RH at 38 °C, non-condensing
4090-9806: Semi-flush trim plate with LED viewing window
4090-9807: Surface-mount box
4090-9810: Mounting bracket (required when using trim plate)
4081-9010 (1 kΩ): Resistor harness for N.O. contacts (series)
4081-9015 (1.5 kΩ): End-of-line (EOL) resistor harness for N.O. contacts
4081-9014 (2.4 kΩ): Resistor harness for N.C. contacts (2 required)
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4007ES addressable fire alarm control panel – powerful, flexible solution for small to medium sized projects, supporting network connectivity and system integration.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Simplex 4017ES addressable fire alarm control panel supports up to 250 IDNet2 points, integrated IDNAC 4A power source, Class A/X digital audio, compatible with TrueAlarm sensors.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Điện thoại cứu hỏa Simplex liên lạc hai chiều giữa trung tâm và lính cứu hỏa, lắp âm/nổi, chống phá hoại, đạt chuẩn UL, FM
View detail
The Simplex 2008FS Fire Alarm Control Unit (FACU) provides flexible initiating circuit supervision and extensive programmable control for areas requiring one to eight initiating zones.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
View detail
2010 © Bản quyền thuộc KPS
Online: 20 | Visitors Counter: 14553186
About | Recruitment | News | Contact Us