info@kps.com.vn
+84 903 709 019
The 4090-9119 is a single-address module (IAM – Individual Addressable Module) for the Simplex fire alarm system, providing:
Unsupervised input monitoring: used to monitor a Normally Open (NO) dry contact, such as a pressure switch or sail switch.
Relay output (Form C, SPDT): to switch external devices (e.g., fans, dampers).
Both input and relay functions operate independently while sharing a single IDNet address, helping save system resources.
Power and communication are supplied directly from the IDNet channel, requiring no separate power source.
Dual-point operation
Provides both an input (monitoring contact state) and a relay output (control via Form C relay) in a single device while using only one fire alarm address.
The input point and relay point can be controlled independently and switched on/off separately as needed.
Unsupervised Input
Input contact is Normally Open (NO), dry contact.
When closed → module reports “Alarm” or “Active” (depending on configuration).
When open → reports “Normal.”
No supervision resistors or extra conditions (like “Short” or “Current-limited”) as in supervised modules.
Maximum wiring distance: 500 ft (152 m) indoors.
Relay Output
Form C (SPDT) relay with one Normally Closed (NC) and one Normally Open (NO) contact.
Relay powered directly from the IDNet channel — no external supply required.
Relay defaults to OFF when first powered up or if IDNet communication is lost.
Communication & Addressing
Uses IDNet channel for both power and data.
Module address set via 8-position DIP switch under resealable cover.
Construction & Installation
Durable thermoplastic housing with metal mounting plate.
Fits in a standard 4-inch square electrical box; adapter/trim plates available if needed.
Blinking LED indicates active IDNet communication.
| Parameter | Value |
|---|---|
| Address capacity | 1 address (single IAM) |
| Input type | Unsupervised dry contact, Normally Open |
| Max input wiring distance | 500 ft (152 m), indoor wiring |
| Relay contact ratings | • 2 A @ 30 VDC (resistive) • 1 A @ 30 VDC (inductive) • 0.5 A @ 120 VAC (resistive) • 0.25 A @ 120 VAC (inductive) |
| Relay type | Form C (SPDT) |
| Power/communication | IDNet channel, one unit load |
| IDNet wiring distance | • From panel to farthest device ≤ 2,500 ft (762 m) • Total wiring length incl. T-Taps ≤ 10,000 ft (3,048 m) |
| Wire size (input/output) | 18–14 AWG (0.82–2.08 mm²) |
| Dimensions | 4-1/8″ H × 4-1/8″ W × 1-3/8″ D ≈ 105 × 105 × 35 mm |
| Operating temperature | 32–120 °F (0–49 °C) |
| Relative humidity | 10–90% RH, non-condensing @ ~32 °C |
4090-9119 – Relay IAM with Unsupervised Input
4090-9813 – Adapter plate for 4-11/16″ (119 mm) square electrical box
4090-9801 – Trim plate for semi-flush mounting (galvanized steel, LED viewing window, includes mounting screws)
4090-9802 – Trim plate for surface mounting
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4007ES addressable fire alarm control panel – powerful, flexible solution for small to medium sized projects, supporting network connectivity and system integration.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Simplex 4017ES addressable fire alarm control panel supports up to 250 IDNet2 points, integrated IDNAC 4A power source, Class A/X digital audio, compatible with TrueAlarm sensors.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Điện thoại cứu hỏa Simplex liên lạc hai chiều giữa trung tâm và lính cứu hỏa, lắp âm/nổi, chống phá hoại, đạt chuẩn UL, FM
View detail
The Simplex 2008FS Fire Alarm Control Unit (FACU) provides flexible initiating circuit supervision and extensive programmable control for areas requiring one to eight initiating zones.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
View detail
2010 © Bản quyền thuộc KPS
Online: 17 | Visitors Counter: 14554969
About | Recruitment | News | Contact Us