The Relay IAM 4090-9002 is an addressable relay module in the IDNet device series from Simplex/Autocall.
It allows the fire alarm control panel (FACP) to remotely switch a relay contact at the installation site. This enables the system to activate or deactivate peripheral devices such as fans, sounders, bells, elevators, or fire doors through the addressable fire alarm network.
Individually addressable: Each Relay IAM is assigned a unique address, allowing the control panel to identify and control it precisely.
Versatile relay output: Can control low-voltage equipment or provide trigger signals to other technical systems.
Powered from IDNet line: No external power required for the logic circuit, reducing wiring costs.
Compact design: Fits inside a standard 1-gang electrical box or protective enclosure.
Integrated status LED: Provides visual indication for easy maintenance and troubleshooting.
International certifications: UL, ULC, FM approvals ensure reliability and compliance for professional fire protection systems.
4090-9002: Relay IAM module
4090-9813: Adapter plate for 4-11/16” (119 mm) square box
4090-9801: Flush-mount plate, galvanized steel, with LED window
4090-9802: Surface-mount plate
Communication: IDNet, occupies 1 address
Power Supply: Directly from IDNet communication line
Relay Output (Form C, SPDT – C, NO, NC):
Power-Limited Circuits:
2 A @ 24 VDC (resistive load)
1 A @ 24 VDC (inductive load)
Nonpower-Limited Circuits:
0.5 A @ 120 VAC (resistive load)
Connections: Screw terminals, 18–14 AWG (0.82–2.08 mm²)
Wiring Distance:
Up to 762 m from the FACP
Total IDNet wiring (with T-Taps): 3048 m
Dimensions: 105 × 105 × 35 mm (4 ⅛” × 4 ⅛” × 1 ⅜”)
Housing Material: Black thermoplastic
Mounting Plate: Galvanized steel
Operating Environment:
Temperature: 0° to 49 °C (32°–120 °F), indoor use only
Humidity: ≤ 93% RH at 38 °C (non-condensing)
Certifications:
CSFM (7300-0026:223)
NYC Department of Buildings – MEA35-93E
Controlling smoke exhaust fans or pressurization fans during fire events.
Shutting down or recalling elevators when fire is detected.
Operating fire-rated doors or magnetic door holders.
Activating auxiliary sounders, bells, or visual indicators in designated areas.
Integration with technical systems (BMS, HVAC, fire pumps, etc.).
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4007ES addressable fire alarm control panel – powerful, flexible solution for small to medium sized projects, supporting network connectivity and system integration.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Simplex 4017ES addressable fire alarm control panel supports up to 250 IDNet2 points, integrated IDNAC 4A power source, Class A/X digital audio, compatible with TrueAlarm sensors.
View detail
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
View detail
Điện thoại cứu hỏa Simplex liên lạc hai chiều giữa trung tâm và lính cứu hỏa, lắp âm/nổi, chống phá hoại, đạt chuẩn UL, FM
View detail
The Simplex 2008FS Fire Alarm Control Unit (FACU) provides flexible initiating circuit supervision and extensive programmable control for areas requiring one to eight initiating zones.
View detail
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
View detail
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
View detail
2010 © Bản quyền thuộc KPS
Online: 15 | Visitors Counter: 14254833
About | Recruitment | News | Contact Us