Active output DC24V/1A

TECHNICAL NUMBERS
| Operating Voltage | Loop: 24V (16V~28V) Power: DC20V~DC28V |
| Standby Current | Loop≤0.42mA Power≤2.00mA |
| Action Current | Loop≤1.34mA Power≤18.00mA |
| Output Capacity | Output contact capacity 30VDC/2A |
| Output control mode |
Continuous or Pulse ( Relay N/O, 10 seconds action duration) |
| Input cable check | 4k7 OHM EOLR |
| Output cable check | Fault on open short-circuit on-circuit and output port |
| Programming Method |
Electronically addressed |
| Code Range | One address within 1~242. |
| Input Indicator | Red. Flashes when polling. Illuminates in action. Double flashes for low power. 2.5Hz 50% duty cycle for cable fault. |
| Output indicator | Red. Lit when output activated. 2.5Hz 50% duty cycle for cable fault. |
| Ingress Protection Rating |
IP30 |
| Operating Temperature |
-10°C ~+55°C |
| Relative Humidity | ≤93%, non condensing |
| Material of Enclosure |
ABS white |
| Dimension (L×W×H) |
86mm×86mm×41mm (with base) |
| Weight | About 96.6g (with base) |