info@kps.com.vn
+84 903 709 019
The GST Fire Alarm System is an automatic fire alarm system designed to detect and alert when there are signs of fire or smoke in an area. It is commonly used in buildings, factories, industrial facilities, or areas with high fire risks to ensure the safety of people and property. Key Features of the GST Automatic Fire Alarm System: - Digital Technology: Enhances accuracy in detecting smoke, heat, or other fire indicators. - Early Fire Detection: Minimizes reaction time to incidents. - Easy Integration and Scalability: Suitable for small installations as well as large buildings and complex industrial areas. - Centralized Control Integration: Supports linking multiple central panels for efficient management across different zones in the system. - Wide Compatibility: Supports various sensor types and other peripheral devices. - BMS and Automatic Fire Suppression Integration: Compatible with building management systems (BMS) and automated fire suppression systems. - User-Friendly Central Panel: Features a clear interface that displays system status and incident locations. Includes event logging for easy review and analysis. - Cost-Effective: Offers reasonable installation and maintenance costs compared to similar systems, making it suitable for various investment budgets. - Smart Alerting System: Delivers alarms and transmits signals to relevant units immediately via phone, email, or mobile apps in case of an incident. - International Compliance: Meets global standards such as EN, UL, and CE for safety and quality assurance. Common Applications: - Residential and commercial buildings - Industrial and manufacturing facilities - Public infrastructure - Hotels and resorts - Specialized constructions - High-risk fire areas - Large and complex projects
Passive Remote Control Room Indicator GST C-9314P PIR LED
Passive Remote Control Room Indicator GST C-9314P PIR LED
Passive Remote Control Room Indicator GST C-9314P PIR LED
Passive Remote Control Room Indicator GST C-9314P PIR LED
GST-CRT-EN Graphic Monitor Center is fire alarm system monitoring software. With a user-friendly interface, the software supports 8 remote client stations plus one local monitoring station, enabling complete monitoring and control of GST fire alarm control panels, including GST1500H-EN, GST9000H-EN, etc.
The DI-M9319 Digital Zone Monitoring Module (module) is designed to connect to conventional fire detectors. When any device connects to the alarm module, the module transmits a signal to the fire alarm control panel (FACP), which then generates a fire alarm and displays the module's address.
In fire alarm systems, local loop short circuits frequently occur, affecting the entire system.
JB-QB-GST200H-S / JB-QB-GST200H2-S Addressable Fire Alarm Control Panel
GST 24VDC-5A auxiliary power supply for fire alarm system PSU24-5
Passive Remote Control Room Indicator GST C-9314P PIR LED
Passive Remote Control Room Indicator GST C-9314P PIR LED
Passive Remote Control Room Indicator GST C-9314P PIR LED
Passive Remote Control Room Indicator GST C-9314P PIR LED
Passive Remote Control Room Indicator GST C-9314P PIR LED
Passive Remote Control Room Indicator GST C-9314P PIR LED
The Bosch Fire Alarm System is one of the advanced solutions for early detection and warning of fires. Bosch offers a range of products and solutions for fire alarm systems, including sensors, control devices, and management software. Key Features of the Bosch Automatic Fire Alarm System: - Diverse and Accurate Sensors: Smoke sensors, heat sensors, CO2 sensors, and combination sensors. - Advanced Technology for highly accurate fire detection, minimizing false alarms. - Smart Management System: Remote monitoring and centralized management features. - Integration with Other Systems: Compatibility with security systems and Building Management Systems (BMS). - Advanced Algorithms and Technology to reduce false alarms, ensuring the system only triggers when there is a genuine fire risk. - Self-testing and Recovery: The system can automatically test itself and recover after an incident, minimizing downtime and maintenance costs. - Scalability and Configurability: Easy to expand and reconfigure to meet the needs of different building sizes, from small buildings to large complexes. - Multi-channel Alerts: Notifications through sound, signal lights, and alerts via phone or email. - Optimized Design to reduce maintenance and operational costs while maintaining high efficiency in fire detection.
Bosch AVENAR Panel 8000 fire alarm control panel, modular design, expandable to 32 loops, touchscreen display.
The Simplex automatic fire alarm system is an advanced fire safety solution, designed to quickly detect and warn of fire risks early. With sensitive sensor technology, flexible connectivity and high reliability.
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
The Simplex 2008FS Fire Alarm Control Unit (FACU) provides flexible initiating circuit supervision and extensive programmable control for areas requiring one to eight initiating zones.
The 4098-5291 Photo/Heat Sensor is part of the Foundation Series, using MX Technology to interface with Simplex 2050 and 2250 FACUs.
The 4098-5292 Photoelectric Sensor is a Foundation Series sensor that uses MX Technology to interface with Simplex 2050 and 2250 FACUs. It is specifically designed to detect smoke with high sensitivity and is resistant to dust and insects.
This is a Visible Only (V/O) device — a ceiling-mounted, individually addressed strobe light, connected to and controlled directly by the Simplex fire alarm control panel via the two-wire IDNAC SLC signal line. The device receives power, supervision signals and control commands from the same pair of wires.
The 4098-5293 Heat Sensor is part of the Foundation Series, using MX Technology to interface with Simplex 2050 and 2250 FACUs. It is designed to detect abnormal temperatures, making it ideal for dusty environments or locations where smoke sensors are not suitable.
Simplex IDNet Addressable Modules add addressing, monitoring & control to common devices, enhancing safety and system integration.
4090-5259 is an MX Relay IAM used by FACU (Fire Alarm Control Unit) to control Form C (SPDT) contacts at remote locations via MX Digital addressable communications (data transmission + power supply).
Simplex rechargeable sealed batteries are specifically designed for fire alarm systems and other system applications, ensuring stable and reliable discharge and charge characteristics. The electrolyte technology is fixed in the absorption separator layer, ensuring the battery reaches its rated capacity from the very first cycle.
Simplex's Connected Services Gateway (CSG) is an intelligent communication card for reporting systems.
Simplex optical smoke detector (4098-5601 & 4098-5603) uses TrueAlarm technology with integrated processing chip to analyze signals from the optical chamber, to intelligently detect smoke and minimize false alarms.
Simplex Heat Detectors (Models 4098-5610, 5611, 5612, 5613) are designed to detect fire conditions by monitoring either a fixed temperature or a rate-of-rise.
Simplex 4004R Suppression Releasing Panel là một bảng điều khiển chuyên dụng trong hệ thống báo cháy, được thiết kế đặc biệt để điều hành hoạt động xả chất chữa cháy tự động (suppression release) như ngưng kết khí (agent release), hệ thống phun Deluge hoặc Preaction sprinkler.
The Simplex 4003EC is a Voice Control Unit (VCU) that adds voice message and audio signalling functionality to central fire alarm systems that do not have voice functionality.
The Simplex 4098-9714 Smoke Sensor is a Photoelectric Smoke Sensor from the Simplex TrueAlarm Analog Sensors series. It uses a steady pulse infrared LED and a photodiode to detect smoke particles in the sensing chamber.
The TrueAlarm addressable heat sensor model 4098-9733 is an electronic heat detector for Simplex addressable fire alarm systems. The sensor uses microprocessor technology to monitor ambient temperature, providing accurate warnings in the event of abnormal temperature increases.
The Simplex 4098-9734 High-Temperature Heat Sensor is part of the TrueAlarm system manufactured by Simplex/JCI. This is an analog addressable heat sensor that detects high ambient temperatures and is self-recovering.
The 4098-XAD is an addressable in-duct smoke detector (IGF) that uses aspiration technology combined with TrueAlarm optical smoke sensors to detect smoke in HVAC ducts or hard-to-reach areas. It integrates environmental compensation, airflow monitoring, filter replacement, and remote monitoring and testing capabilities, providing high reliability and ease of maintenance.
Simplex 4098-9020 reflective beam smoke detector controller is a controller for reflective beam smoke detectors from Simplex, specialized in detecting smoke in large spaces such as warehouses, factories or high halls.
Detector Head model 5000-031 is an auto-aligning infrared beam smoke detector used as an add-on to a beam detection system such as the Fireray 5000 or Simplex 4098-9019.
MX Addressable Multi-Sensors của Simplex 4098-52xx
The 4098-5255 MX Photo/Heat Sensor is a multi-purpose sensor in the MX series, designed to detect smoke and heat simultaneously.
The 4098-5256 MX Photo Sensor is a photoelectric smoke detector designed to interface with the Simplex MX Addressable System. It is a smoke detector (no heat sensor) and is addressable — meaning it transmits signals directly to the MX Loop Module.
The 4098-5257 MX Heat Sensor is a temperature-only sensor from the Simplex MX addressable sensor family. It uses a high-quality thermistor with very low thermal mass, providing fast and accurate response to temperature changes to assess fire conditions.
Simplex 4098-5265 (MX Photo/Heat Sensor-Isolator) is a Simplex MX Addressable sensor head, integrating both photoelectric and heat sensors, and equipped with an isolator to protect the signal loop in the event of a short circuit. This design is suitable for detecting both smoke and heat fires more accurately and safely.
The 4098-5266 MX Photo Sensor-Isolator is a photoelectric smoke sensor from Simplex's MX Technology addressable family, featuring an integrated isolator. This design not only allows the sensor to detect smoke, but also protects the signal loop from short circuits, ensuring continuous, stable operation.
The Simplex 4098-5267 MX Heat Sensor-Isolator is a heat-only sensor that uses Simplex's MX addressable technology.
Cảm biến 4098-5268 MX Photo/Heat/CO Sensor-Isolator là một thiết bị đa cảm biến (ba cảm biến) trong hệ MX addressable của Simplex
The Simplex® 4098-X conventional smoke and heat detectors are advanced fire detection devices widely applied in professional fire alarm systems. With modern microprocessor technology, the product provides fast and accurate fire detection while minimizing false alarms, ensuring safety for people and property.
Simplex 4099-5203/5204 Addressable Callpoints – MX Loop fire alarm push button, LED display, easy to maintain, for indoor & outdoor use (IP67).
Simplex 2099 Series Manual Fire Alarm Stations are manual fire alarm activation devices, designed to be wall mounted and manually operated, compatible with conventional non-addressable fire alarm systems.
Simplex SO Addressable Ceiling Mounted Fire Alarm Loudspeakers are used for addressable fire alarm systems, connected and controlled via the IDNAC Signaling Line Circuit (SLC).
The Simplex TrueAlert S/O Addressable Wall-Mounted Public Address Speaker is controlled via the IDNAC Signal Line Circuit (SLC), with audio sourced from a separate circuit NAC. Supports Class B T-tap connections for both audio and SLC, reducing wiring costs and distances.
The addressable loudspeaker (S/O) and loudspeaker indicator (S/V) are powered, monitored and controlled entirely via a compatible Simplex® Fire Alarm Control Unit (FACU). Operation requires an IDNAC SLC (for power and control) along with a separate audio circuit (for loudspeaker output).
Units are individually powered, addressed, and controlled via Simplex FACU IDNAC SLC, with loudspeakers using dedicated NAC audio circuitry; support for T-tap (Class B) wiring reduces cost and cable length; mounts in a standard 4x4 in. 54 mm deep electrical box or a weatherproof/surfaced WP back box; models are available with a frequency range of 400–4000 Hz (standard) or 200–10,000 Hz (High Fidelity), and the -BA version is assembled in the USA.
Units are individually powered, addressed, and controlled via Simplex FACU IDNAC SLC, with loudspeakers using dedicated NAC audio circuitry; support for T-tap (Class B) wiring reduces cost and cable length; mounts in a standard 4x4 in. 54 mm deep electrical box or a weatherproof/surfaced WP back box; models are available with a frequency range of 400–4000 Hz (standard) or 200–10,000 Hz (High Fidelity), and the -BA version is assembled in the USA.
The TrueAlert ES addressable fire alarm siren is a sounder that is powered, monitored and controlled directly from the Simplex IDNAC SLC fire alarm panel. It ensures increased circuit monitoring reliability and saves wiring thanks to a stable 29 VDC voltage even when running on battery backup.
The 49AO Ceiling Siren is an individually addressable, audible-only alarm device that operates entirely via an IDNAC SLC two-wire loop from a Simplex control panel. The system uses a stable 29 VDC power supply, providing efficient operation in both normal and backup power modes, while reducing current consumption and increasing line capacity.
The Simplex 49AV is a wall-mounted audible/visual (A/V) notification device – combining pattern and flash – from the TrueAlert ES series. It is connected directly to the fire alarm control panel via an IDNAC SLC line, receiving power, monitoring and controlling the signal from there.
This is a combined horn and strobe device, individually addressed, mounted on the ceiling and connected directly to the Simplex fire alarm control panel via the IDNAC SLC (Signaling Line Circuit) signal line. The device receives power, monitoring and control commands simultaneously over two wires.
This is a Visible Only (V/O) device — a ceiling-mounted, individually addressed strobe light, connected to and controlled directly by the Simplex fire alarm control panel via the two-wire IDNAC SLC signal line. The device receives power, supervision signals and control commands from the same pair of wires.
Wall-mounted weatherproof alarm devices include wall-mounted addressable (addressable) fire alarm devices, designed to be water and dust resistant (weatherproof), for both indoor and outdoor use, suitable for environments with extreme temperature or humidity conditions.
The Model Series 49AV (TrueAlert ES) is a ceiling mounted, weatherproof (weatherproof) combination sounder (buzzer) and flasher (xenon strobe) addressable (addressable) device. It operates via a double-wired IDNAC SLC, receiving power, light, audio and monitoring/control signals directly from the Simplex central control panel.
The TrueAlert ES Series 59VO is a visible-only, addressable LED strobe.
TrueAlert ES 59WP is a Simplex outdoor alarm system that incorporates advanced addressable technology, allowing each device to be individually addressable, monitored and controlled from a central location. The system is connected via IDNAC Signaling Line Circuits (SLCs), providing a stable 29 VDC voltage, ensuring stable operation on both main and backup power sources.
This is the Audible/Visible (A/V) line of Simplex's TrueAlert ES system: each device is individually addressable and receives signal, monitoring, and power from the central board via the IDNAC SLC circuit, providing a stable power supply of ~29 VDC.
TrueAlert ES Multi-Tone Addressable Horn (49MT Series) is a multi-tone sounder that can receive signals, power and monitor from the control center via the IDNAC SLC signal line, with a stable voltage of about 29 VDC.
This device is an addressable LED text display panel in the Simplex TrueAlert ES fire alarm system. It displays LED text alarm messages, receives commands and monitoring via IDNet signaling, operates on 24 VDC power from the system, and has battery backup capability from the fire alarm control center.
The Simplex 4902 Series is a multi-application speaker designed for use in emergency fire alarm systems, and can also play background music. The speaker is moisture-resistant, has a wide frequency response and low distortion, suitable for fire alarm and public address sound.
SmartSync Two-Wire Operation, Non-Addressable Mini-Horns are mini-horns, non-addressable, using SmartSync two-wire technology. This is a unique control method that requires only two wires on the Notification Appliance Circuit (NAC) to control both the horn and the flashing light (if present) for audible and/or visual warnings.
The Simplex 4901-9820 is a TrueAlert series non-addressable electronic horn. It is a high-intensity audible warning device that operates on the Notification Appliance Circuit (NAC) and has two control modes: Free-Run: sounds directly on the signal from the NAC. SmartSync: controls the sound via two wires along with devices such as strobe lights, saving wires and installing on the same circuit while still allowing each device to be turned off independently.
Simplex Horn/Strobe are non-addressable, 4-Wire Operational horn and strobe devices that separately control two components: NAC1 (first Notification Appliance Circuit): controls the strobe NAC2 (second circuit): controls the horn MEA (New York City Department of Buildings) approved — certified for use in NYC (MEA35-93E)
Visible Notification Appliances for Free-Run Operation are strobe devices in fire alarm systems. They use a 24VDC xenon flash lamp to emit a flashing light signal, attracting attention when an alarm is activated.
The S4906-0002 (Horn/Strobe A/V) is a TrueAlert non-addressable horn/xenon strobe combination warning device that supports two-wire SmartSync. Designed for both wall and ceiling mounting, it includes an electronic horn and synchronized strobe for a clear, effective warning effect.
Visible Notification Appliances for Free-Run Operation are strobe devices in fire alarm systems. They use a 24VDC xenon flash lamp to emit a flashing light signal, attracting attention when an alarm is activated.
This is a line of outdoor fire alarm devices from Simplex (Johnson Controls), specially designed to operate in harsh environments. The device can be a fire alarm light (strobe) or a horn + light (horn/strobe), emitting a warning signal with flashing light and sound when there is a fire.
The TrueAlert Multi-Candela S4906-0011 fire alarm device is a high intensity strobe and horn/strobe combination, operating on 24 VDC power, used in Simplex (Johnson Controls) fire alarm systems.
TrueAlert Multi-Candela S4906 is a Visible Notification Appliance that uses a high-powered xenon flashing light to provide visual warning of a fire. The product is designed for both wall mount and ceiling mount, suitable for many different installation environments.
The S49CMTV-X multi-tone horn/strobe is a combination siren and strobe from the TrueAlert non-addressable line of Simplex (Johnson Controls). This is a fire alarm device that integrates sound and light for use in emergency warning systems (fire alarm), operates without a separate network address, is suitable for wall mounting and uses 24 VDC power.
TrueSite Workstation (TSW) is Simplex's new system platform, managing the entire reporting and safety system from a central graphical control panel on the computer.
Fire Alarm Ethernet Switch is specially designed for fire alarm network (Fire Alarm LAN), connecting TrueSite Workstation Server with Remote Clients.
TrueSite Building System Information Unit (BSIU) S4190-0030 is a graphical, PC-based fire alarm network monitoring and control system software designed to add functionality to the Simplex fire alarm system. This version is suitable for many small-scale facilities (such as schools, clinics, small buildings), providing access to the advanced features of TrueSite Workstation but using common hardware, helping to save costs.
Simplex Incident Manager (SIM) is an advanced fire alarm network control platform that enables centralized management, monitoring and coordination of large-scale fire alarm systems. The software runs on a SIM server or remote device, meeting modern safety and security requirements.
Remote Client is used to connect to Simplex Incident Manager (SIM) Server via HTTPS. Supports up to 60 users at the same time. There are 2 types: Supervised Remote Client → runs SIM Client software on Windows, has full control functions like a server, if the connection is lost, it will report Trouble. Unsupervised Remote Client → runs on Chrome (any OS), view-only.
SafeLINC FPII (model S4100-0062) is an Internet communication module developed by Simplex / Johnson Controls, used to connect the fire alarm control panel (FACP) to the LAN/Internet. The device allows remote monitoring and management of the fire alarm system status via a web browser in a safe and convenient way.
The IAM (Individual Addressable Module) S4090-0001 is a single addressable communication module for use in Simplex/Autocall IDNet or MAPNET II addressable fire alarm systems. The device allows the connection of dry-contacts of switches, relays or other peripheral devices to the fire alarm system to turn them into individually addressable monitoring points on the signal path.
Relay IAM 4090-9002 is an addressable relay module belonging to the Simplex/Autocall IDNet communication device series. The device allows the fire alarm control panel (FACP) to control the on/off of a relay contact at the installation location. Thanks to that, the center can activate or deactivate peripheral devices such as fans, sirens, bells, elevators, fire doors, etc. through the addressable fire alarm system.
The Simplex “Zone Adapter Module” (ZAM) from the models 4090-9101 and 4090-9106 allows integration of zones (areas) using conventional reporting heads (conventional devices) into an address reporting system (IDNet or MAPNET II). The 4090-9101 is Class B (class B), supporting 2-wire or 4-wire initiating devices and has the ability to reset the 4-wire type. The 4090-9106 is Class A (class A zone, instantaneous with loop/bidirectional capability), 2-wire devices supported only.
The 4090-9121 Security Monitor IAM module is a single addressable interface device (IAM) for monitoring security devices such as magnetic door/window switches, dry-contact switches in fire alarm/security control systems, used with Simplex/Autocall fire alarm control panels 4100ES, 4100U and 4010ES via IDNet transmission. It allows the module to distinguish the status of the monitoring zone (contact) such as: Open, Normal, Abnormal and Short.
4090-9116 Addressable IDNet Communication Isolator is an IDNet communication circuit isolator (isolator) used in addressable (addressable) fire alarm systems. Purpose: when a fault such as a short circuit (short circuit) or earth leakage (earth fault) occurs on the signal transmission line (Signal Line Circuit, SLC, or IDNet), the device will isolate the faulty circuit, so that the rest of the system continues to operate normally. It is integrated with an address (addressable) to be able to manage and monitor the fire alarm control panel (Fire Alarm Control Panel - FACP).
4090-9120 is a single address module (Six Point Module) of the Simplex fire alarm system, allowing: 4 T-Sense inputs (supervised inputs): monitor normally open (NO) contacts, distinguish 4 states: Normal (open circuit with EOL resistor) Open Circuit (lost EOL → Trouble) Short (direct contact closure → e.g. Damper Closed or Fire Alarm) Current Limited (contact closure via current limiting resistor → e.g. Damper Open or Supervisory) 2 Relay outputs (Form C, SPDT): control peripheral devices (e.g. fans, dampers, motors, valves). Occupies only 1 IDNet address, but actually provides up to 6 I/O points (displayed as sub-points on the control panel).
Signal IAM là Signal Individual Addressable Module. Đây là một module (IAM) dùng trong hệ thống báo cháy địa chỉ (addressable fire alarm system) của Simplex, nối giữa bảng điều khiển báo cháy trung tâm (FACP / FACU) với các thiết bị thông báo (notification appliances) như còi, đèn chớp (horn/strobe), loa, v.v.
Individual Addressable Module (IAM) with 2 Form C contacts (DPDT), allows IDNet or MAPNET II fire alarm panels to remotely control and monitor devices such as fans, dampers, elevator capture, pressure valves, HVAC, etc. Only occupies 1 address but can control 2 independent contacts, optimizing the number of addresses on the loop.
The Individual Addressable Relay Module (IAM) is capable of providing 2 independent contacts: 1 normally open contact (Form A – NO) 1 normally closed contact (Form B – NC) Both contacts carry a load of 8 A and occupy only 1 IDNet address. The device is powered directly from the transmission line, no auxiliary power is required.
The Multiple I/O Module uses MX Technology, allowing monitoring of 3 independent Class B inputs (N.O or N.C) and control of 2 Form C relay outputs (dry contact, volt-free). All are powered directly from the MX loop without the need for an auxiliary power source, and occupy only 1 address, but have a total of 5 sub-points (3 inputs + 2 outputs).
Simplex TrueAlert ES 59AO is an addressable fire alarm line controlled via SLC (Signaling Line Circuit) using IDNAC (Intelligent Device NAC) technology. This is a modern device that integrates an audible horn and allows simultaneous use with a strobe on the same line.
Simplex TrueAlert ES 59AV is a combination horn and strobe fire alarm device, operating in an addressable manner, receiving power, signals and monitoring directly from the fire alarm panel via the IDNAC SLC circuit. Designed to save wiring and optimize performance even when switching to backup batteries.
TrueSite Incident Commander (TSIC) is an all-in-one workstation (touch screen + software) that allows monitoring, display and control of the Simplex fire alarm network.
Simplex fire alarm speakers/lights are a type of warning device with both sound and light (Audio-Visual, abbreviated as A/V) including: Speaker: emits a siren or voice alarm. Strobe: a clear flashing light signal, supporting the hearing impaired or in noisy environments.
The Simplex 4100-1292 Remote Command Center displays fire alarm status remotely, features a 2x40 character LCD, RUI connectivity, and is for use with the 4100ES system.
Simplex 4100-9617 – Remote annunciator ES Touch Screen 8”, displays fire alarm status remotely, connects to 4100ES, powered by FACU.
The Remote Annunciator Simplex 4100-9616 integrates an 8-inch ES Touch Screen, displaying and remotely controlling fire alarms for the 4100ES system.
Simplex 2008-9101 is a standard fire alarm control panel from the Foundation Series, supporting up to 8 fire alarm zones.
The Simplex 2050-9101 addressable fire alarm panel supports 50 MX devices, 2 NAC synchronization, and IP-DACT connectivity via PSTN, LAN, and 4G.
The Simplex 4090-5260 Monitor ZAM module allows monitoring of typical 2-wire equipment zones via MX, compatible with 2050, 2250, and 4100ES control panels, and UL 864 compliant.
Simplex 4099-5214 addressable fire alarm push button, MX standard, single action, compatible with 2050, 2250, 4007ES control panels, UL Listed.
Simplex 4099-5216 addressable fire alarm push button, double action breakglass, MX protocol, UL Listed, for use with 2050, 2250, and 4007ES control panels.
Simplex 4098-5686 is a 4-wire duct smoke detector with housing and relay, for monitoring smoke in HVAC systems, UL certified.
Simplex 4098-9688 is a 2-wire duct smoke detector with integrated housing and relay, for HVAC monitoring, compatible with Simplex fire alarm panels.
Simplex 4098-9686 is a 4-wire duct smoke detector with integrated housing and relay, for monitoring smoke in HVAC systems, UL certified.
The Simplex 4098-5611 heat detector detects a fixed temperature of 135°F, is suitable for 2-wire/4-wire conventional fire alarm systems, is stable, and has few false alarms.
The Simplex 4009 IDNet NAC Extender expands 4–8 NAC circuits, has an 8A power rating, supports IDNet and standard NAC, and features TrueAlert bell and light synchronization.
Simplex 4009-9301 is an IDNet 8A NAC expansion module, supporting 4/8 Class A/B circuits, TrueAlert synchronization, for use with Simplex fire alarm systems.
Simplex 49CMTV-WRF TrueAlert fire alarm siren, 520Hz sound, multi-candela strobe, SmartSync, NFPA 72 & ADA compliant.
Simplex 49CMTV-WRF-BA is a 520Hz red TrueAlert horn/strobe with multi-candela strobe, SmartSync, for use in addressless fire alarm systems.
Simplex 4903-925x wall-mounted fire alarm siren/light, 4-wire, Free-Run/Sync, multiple brightness levels 15–110cd, NFPA & UL compliant.
Simplex 4903-9255 is a wall-mounted audio/Visible Notification Appliance, using 4-wire power.
Simplex 2606-9111 LED Annunciator is a remote LED annunciator (secondary display panel) belonging to the Foundation Series.
The Simplex 4904-917x fire alarm indicator light is wall-mounted, strobe 15–110cd, Free-Run/Sync, can be mounted vertically or horizontally, and is compatible with the Simplex fire alarm system.
Simplex 4906 TrueAlert multi-candela strobe delivers synchronized visual fire alarms with selectable 15–110 cd and SmartSync control.
Simplex 4906 TrueAlert Horn/Strobe ceiling-mounted, multi-level illumination 15–185cd, synchronized horn and light, compatible with Simplex fire alarm system.
The Simplex 2004FS 2004-9101 is a standard 4-zone fire alarm control panel, offering stable operation, battery backup support, and suitability for small to medium-sized buildings.
Simplex Foundation Series 2050FS & 2250FS fire alarm system – smart, flexible, safe fire alarm center for all projects.
The Simplex 4098-5290 addressable smoke detector uses MX technology, provides early smoke detection, is compatible with 2050FS and 2250FS control panels, and is UL compliant.
The Simplex 2250-9101 addressable fire alarm control panel supports 250 MX devices, 4 NAC 3A, and IP-DACT connectivity via PSTN, LAN, and 4G.
The Simplex 4100-1244 is a remote microphone module for the EVAC 4100ES/4100U system, supporting emergency announcements and featuring two front panel slots.
Autocall 4099-5215 is an MX addressable dual-action breakglass fire alarm push button with fast signal transmission, continuous monitoring, and UL certification.
The 4098-5293 Heat Sensor is part of the Foundation Series, using MX Technology to interface with Simplex 2050 and 2250 FACUs. It is designed to detect abnormal temperatures, making it ideal for dusty environments or locations where smoke sensors are not suitable.
Simplex smoke + heat detector (Models 4098-5602, 4098-5604) is a combination photoelectric and thermistor smoke detector.
Simplex 4010ES – addressable fire alarm panel, supports 250-1,000 points, IP networking, touch screen, compatible with TrueAlarm & TrueAlert ES.
The Simplex 2004FS fire alarm control unit (FACU) delivers flexible initiating circuit monitoring for areas requiring one to four initiating zones.
The Simplex 4098-5685 is a 2-wire duct smoke detector with integrated housing and relay, used for HVAC system monitoring and early smoke detection.
KENTEC fire is based in the UK and has operated for more than over 30 years, specializing in manufacturing equipments and solutions for intelligent fire alarm systems according to European standards EN54 UL/FM. KPS company is an official distributor in Vietnam of KENTECFIRE
2010 © Bản quyền thuộc KPS
Online: 37 | Visitors Counter: 17089998