Tower UPS system - Tower series N-series Tycon Network Tower UPS N-series 1KVA - 10KVA is a new generation UPS line. Apply the latest R&D (research and development) achievements and combine them with application experience. Taking advantage of advanced DSP digital control technology, it effectively improves system performance and reliability, achieving higher levels of compression and energy storage. Besides, to meet all the needs of different customers, as a high-end online UPS line, N series can provide reliable power for small servers, local networks, industrial workstations. industrial, and other electronic devices.
Adopting advanced DSP digital control technology, optimally improve system performance and efficiency and achieve higher heights in compression and energy storage.
Besides, it can meet all the unique needs of each customer, the Series 1 - 10KVA UPS system provides users with very rich expansion functions that can be configured flexibly depending on needs.
- Output power factor 0.8
The output power factor PF(Power factor) 0.8 is more suitable for the modern trend of electrical equipment and can carry more load. With the new ECO (Economic) function, the system efficiency can reach 94%, it reduces the power consumption of the UPS and saves users' costs.
- PFC input input
Adopting PFC digital input control technology, input Power Factor can be greater than 0.98, it avoids pollution to the power grid, saves energy, and also reduces costs.
- Digital control at DC-DC Converter
Series 1 -3KVA UPS system uses digital control in DC-DC converter instead of Analog control like in the past and it is safer.
- Wide range of input voltage
Extremely wide input voltage and frequency range even for use in very poor power environments such as remote power supply locations. It reduces the frequency of battery discharge so that battery life can be extended.
- Perfect protection
UPS includes I/P and O/P over protection layer, short voltage protection, overload protection, short circuit protection, over temperature protection, low voltage warning protection and battery overload protection.... Ensures the stability and safety of running system.
With bypass function, when output overload or UPS failure, can switch to bypass without interruption, and supply power to main power supply, and also output alarm information.
With the L and N line detection function, the danger caused by the inversion of the L and N lines can be prevented.
- Cold start and main power start function
For emergencies, the UPS can be started by battery directly when the power supply is abnormal.
UPS can start directly without battery, can be used for high precision stabilizer.
- Applicable to generators
With a wide range of input voltage and frequency, it can effectively isolate adverse sources from the generator, which can provide clean, safe and stable load power.
- Smart battery management
It adopts three-step charging intelligent management technology, to effectively extend battery life and reduce battery maintenance times. The battery can self-check to find problems promptly.
Back of UPS Tycon N1000 with initial circuit records connected to the device

- Input:
- Output:
- Rated frequency:
- Switching speed
Inverter overload capacity: 105%-150% 30s switch to bypass mode to alarm; >150% 300ms enters bypass mode for alarm
- Battery:
- Charging method: Three-stage
- System operating environment: