info@kps.com.vn
+84 903 709 019
The Legrand Keor DK 311345 is an On-line Double Conversion UPS (VFI-SS-11) with a capacity of 1000 VA / 1000 W, providing continuous and stable power for sensitive equipment such as servers, network systems, and industrial devices.
It features a flexible convertible design for tower or 19” rack (2U) installation, equipped with a touchscreen display and intuitive LED status bar for easy monitoring and operation.
On-line Double Conversion (VFI-SS-11) technology delivers a pure sinewave output, fully isolating connected equipment from electrical noise and voltage fluctuations.
High efficiency up to 92%, saving energy and reducing heat generation.
Wide input voltage range (176–280 V) ensures stable operation even under fluctuating mains conditions.
High input power factor (>0.99) minimizes power loss and optimizes performance.
8A charging current supports external battery expansion for longer backup time.
Integrated EPO, SNMP, ROO, and dry contacts allow seamless integration into centralized management systems.
Low noise level ( makes it ideal for quiet environments such as offices or control rooms.
Compact 2U design with IP20 protection, compliant with EN 62040-1, EN 62040-2, and EN 62040-3 international standards.
| Parameter | Specification |
|---|---|
| Rated Power (VA) | 1000 VA |
| Active Power (W) | 1000 W |
| Technology | On-line Double Conversion (VFI-SS-11) |
| Output Waveform | Sinusoidal |
| Installation Type | Convertible Tower / 19" Rack |
| Nominal Voltage | 230 V |
| Nominal Frequency | 50/60 Hz ±5% (autosensing) |
| Input Voltage Range | 176 V – 280 V |
| Input Current THD | < 5% |
| Input Power Factor | > 0.99 |
| Output Voltage | 230 V ±1% |
| Output Frequency | 50/60 Hz (configurable via LCD) ±0.1% |
| Efficiency | Up to 92% |
| Crest Factor | 3:1 |
| Output Voltage THD | < 3% (linear load) |
| Output Voltage Deviation | ±1% |
| Automatic Bypass | Yes |
| External Maintenance Bypass | Optional |
| Internal Backup Time | - minutes |
| External Battery Expansion | Yes |
| Charging Current | 8 A |
| Display | Touchscreen with LED Status Bar |
| Communication Ports | ROO, USB, RS232 |
| Network Interface | SNMP |
| Reverse Fan Protection | Yes |
| Emergency Power Off (EPO) | Yes |
| Dry Contacts | Integrated |
| Dimensions (H x W x D) | 440 x 88 (2U) x 454 mm |
| Net Weight | x kg |
| Operating Temperature | 0 – 40 °C |
| Protection Degree | IP 20 |
| Relative Humidity | < 95%, non-condensing |
| Noise Level at 1 m | < 50 dBA |
| Compliance Standards | EN 62040-1, EN 62040-2, EN 62040-3 |
2010 © Bản quyền thuộc KPS