info@kps.com.vn
+84 903 709 019
The Legrand Keor DK 311335 (3kVA / 2.7kW) is an On-line Double Conversion UPS (VFI-SS-11) designed for IT systems, security equipment, telecommunications, and light industrial applications.
It provides optimal power stability and comprehensive protection against power disturbances such as sags, surges, and electrical noise — ensuring continuous and reliable operation for connected equipment.
With its slim 2U design, the UPS can be installed either as a rack-mounted or tower unit, offering flexibility for various installation environments.
The Keor DK 3000 (2U) is an ideal solution for medium-sized data centers, servers, network devices, and surveillance systems that demand high performance and absolute reliability.
On-line Double Conversion technology delivers a pure, stable, and clean sinewave output.
3kVA / 2.7kW output capacity supports multiple critical loads simultaneously.
Flexible 2U convertible design — easily switchable between rack and tower configurations.
Integrated communication interfaces (RS232, USB, SNMP slot) enable remote monitoring and management.
Compatible with Legrand management software for real-time UPS monitoring and safe system shutdown.
Supports external battery connection (EBC) to extend backup time as required.
Quiet operation suitable for office and control room environments.
High efficiency (>90%), reducing energy consumption and operational costs.
| Parameter | Specification |
|---|---|
| Rated Power (VA) | 3000 VA |
| Active Power (W) | 2700 W |
| Technology | On-line Double Conversion (VFI-SS-11) |
| Output Waveform | Sinusoidal |
| Installation Type | Convertible Tower / 19" Rack |
| Input Voltage | 230 V |
| Input Frequency | 50/60 Hz ±5% (autosensing) |
| Input Voltage Range | 176 V – 280 V |
| Input Current THD | < 5% |
| Input Power Factor | > 0.99 |
| Output Voltage | 230 V ±1% |
| Output Frequency | 50/60 Hz (configurable via LCD) ±0.1% |
| Efficiency | Up to 93% |
| Crest Factor | 3:1 |
| Output Voltage THD | < 3% (linear load) |
| Output Voltage Deviation | ±1% |
| Automatic Bypass | Yes |
| External Maintenance Bypass | Optional |
| Internal Backup Time | 10 minutes |
| External Battery Expansion | Yes |
| Charging Current | 2 A |
| Display | Touchscreen with LED Status Bar |
| Communication Ports | ROO, USB, RS232 |
| Network Interface | SNMP (optional) |
| Reverse Fan Protection | Yes |
| Emergency Power Off (EPO) | Yes |
| Dry Contacts | Integrated |
| Dimensions (H x W x D) | 440 x 88 (2U) x 640 mm or 440 x 132 (3U) x |
| Battery Cabinet Dimensions (W x H x D) | 440 x 88 (2U) x 583 mm |
| Net Weight | 24 kg |
| Operating Temperature | 0 – 40 °C |
| Protection Degree | IP 20 |
| Relative Humidity | < 95%, non-condensing |
| Noise Level at 1 m | < 50 dBA |
| Compliance Standards | EN 62040-1, EN 62040-2, EN 62040-3 |
2010 © Bản quyền thuộc KPS