info@kps.com.vn
+ 84 903 709 019
|
Technical Specifications |
Simplex Controller |
Dual Simplex Controller |
|
Configuration |
12 x 4 TB (DSA‑N2E7X4‑12AT) |
12 x 4 TB (DSA‑N2C7X4‑12AT) |
|
Power Requirements |
||
|
Nominal Voltage |
100 VAC |
240 VAC |
|
Frequency |
50 to 60 Hz |
|
|
Typical Operating Current |
Low: 3.61 A |
Low: 3.61 A |
|
High: 1.50 A |
High: 1.50 A |
|
|
Maximum Operating Current |
Low: 5.16 A |
Low: 5.16 A |
|
High: 2.15 A |
High: 2.15 A |
|
|
Sequential Drive Group Spin Up |
Low: 4.27 A |
Low: 4.27 A |
|
High: 1.76 A |
High: 1.76 A |
|
|
Simultaneous Drive Spin Up |
Low: 6.81 A |
Low: 6.81 A |
|
High: 2.71 A |
High: 2.71 A |
|
|
System Rating Plate Label |
Low: 9.0 A |
Low: 9.0 A |
|
High: 3.6 A |
High: 3.6 A |
|
|
Power Consumption (Typical Operating Power) |
||
|
KVA |
0.361 |
|
|
AC Watts |
358 |
|
|
BTU/h |
1220 |
|
|
Battery Data |
||
|
Number of Batteries |
2 |
|
|
Battery Type |
Li-ion |
|
|
Weight of Battery |
0.157 kg (0.346 lb) |
|
|
Battery Casing |
Pack |
|
|
Battery Group |
Accumulator |
|
|
System Technical Specifications |
||
|
Chassis |
DSA E2700 controller-drive tray conforms to the 483 mm (19.0 in) rack standard |
|
|
Power Supplies |
Dual redundant, hot-pluggable |
Dual redundant, hot-pluggable |
|
Maximum Disk Drives |
12 x 4 TB, 3.5”, Nearline SAS |
12 x 4 TB, 3.5”, Nearline SAS |
|
Maximum Capacity (RAID‑5 configured) |
40964 GB |
40964 GB |
|
System RAM (DDR2) |
4 GB |
4 GB |
|
Integrated I/O |
2 x 100 Mbps management port; 2 x 1/10 Gigabit Ethernet, copper |
|
|
Remote Management |
Yes (via console port over LAN) |
|
|
Mechanical |
||
|
Dimensions (H x W x D) |
Controller Tray: 86.4 x 482.6 x 552.5 mm |
Shipping Box: 241.3 x 584.2 x 685.8 mm |
|
Weight |
Max Weight: 24.9 kg (Simplex Controller) |
Max Weight: 27 kg (Dual Simplex Controller) |
|
Max Shipping Weight: 29.65 kg (Simplex Controller) |
Max Shipping Weight: 31.75 kg (Dual Simplex Controller) |
|
|
Space Requirements |
||
|
Front—cooling |
Clearance of 760 mm in front of the cabinet |
|
|
Rear—cooling |
Clearance of 610 mm behind the cabinet |
|
|
Front of Chassis—maintenance |
Clearance of 760 mm in front of the chassis |
|
|
Rear of Chassis—maintenance |
Clearance of 610 mm behind the chassis |
|
|
Environment |
||
|
Temperature |
Operating Range (cabinet and system): +10 °C to +40 °C |
Operating Range (cabinet and system): +10 °C to +40 °C |
|
Maximum Rate of Change: 10 °C (50 °F) per hour |
Maximum Rate of Change: 10 °C (50 °F) per hour |
|
|
Storage Range: -10 °C to +50 °C |
Storage Range: -10 °C to +50 °C |
|
|
Relative Humidity (Non-Condensing) |
Operating Range (cabinet and system): 20% to 80% |
Operating Range (cabinet and system): 20% to 80% |
|
Storage Range: 10% to 90% |
Storage Range: 10% to 90% |
|
|
Noise |
||
|
Sound Power (Idle) |
Maximum 65 dB |
|
|
Sound Pressure (Normal Operation) |
Maximum 65 dBA |
|
|
12 Drive Expansion Unit |
12 x 4 TB (DSX‑N1D6X4‑12AT) |
|
|
Power Requirements (Expansion Unit) |
||
|
Nominal Voltage |
100 VAC |
240 VAC |
|
Idle Current |
Low: 2.96 A |
Low: 2.96 A |
|
High: 1.23 A |
High: 1.23 A |
|
|
Maximum Operating Current |
Low: 3.03 A |
Low: 3.03 A |
|
High: 1.26 A |
High: 1.26 A |
|
|
Sequential Drive Group Spin Up |
Low: 4.23 A |
Low: 4.23 A |
|
High: 1.76 A |
High: 1.76 A |
|
|
Simultaneous Drive Spin Up |
Low: 4.43 A |
Low: 4.43 A |
|
High: 1.83 A |
High: 1.83 A |
|
|
System Rating Plate Label |
Low: 7.0 A |
Low: 7.0 A |
|
High: 2.9 A |
High: 2.9 A |
|
|
Power Consumption (Expansion Unit) |
||
|
KVA |
0.276 |
|
|
AC Watts |
276 |
|
|
BTU/h |
954 |
|
|
System Technical Specifications (Expansion Unit) |
||
|
Chassis |
DE1600 controller-drive tray conforms to the 483 mm (19.0 in) rack standard |
|
|
Power Supplies |
Dual redundant, hot-pluggable |
|
|
Maximum Disk Drives |
12 x 4 TB, 3.5”, Nearline SAS |
|
|
Maximum Capacity (RAID‑5 configured) |
40964 GB |
|
|
Integrated I/O |
6 Gb SAS |
|
|
Mechanical (Expansion Unit) |
||
|
Dimensions (H x W x D) |
Drive Tray: 86.4 x 482.6 x 552.5 mm |
Shipping Box: 241.3 x 584.2 x 685.8 mm |
|
Weight |
Max Weight: 27 kg |
Max Shipping Weight: 31.75 kg |
|
Space Requirements (Expansion Unit) |
||
|
Front—cooling |
Clearance of 760 mm in front of the cabinet |
|
|
Rear—cooling |
Clearance of 610 mm behind the cabinet |
|
|
Front of Chassis—maintenance |
Clearance of 760 mm in front of the chassis |
|
|
Rear of Chassis—maintenance |
Clearance of 610 mm behind the chassis |
|
|
Environment (Expansion Unit) |
||
|
Temperature |
Operating Range (cabinet and system): 0 °C to +35 °C |
|
|
Maximum Rate of Change: 10 °C (50 °F) per hour |
||
|
Storage Range: -10 °C to +50 °C |
||
|
Relative Humidity (Non-Condensing) |
Operating Range (cabinet and system): 20% to 80% |
|
|
Storage Range: 10% to 90% |
||
|
Noise (Expansion Unit) |
||
|
Sound Power (Idle) |
Maximum 65 dB |
|
|
Sound Pressure (Normal Operation) |
Maximum 68 dB |
2010 © Bản quyền thuộc KPS
Online: 31 | Visitors Counter: 13520640
About | Recruitment | News | Contact Us