KPS System Corp | Công ty cổ phần Hệ Thống An Ninh Khai Phát

Syncro XT+

Syncro XT+
  • Complies with EN12094-1, EN54-2 and EN54-4
  • 16 detection zones
  • Up to 4 extinguishant areas
  • Dual extinguishant outputs for each area (configurable as Main/Reserve)
  • First and second stage sounder outputs for each area
  • First and second stage volt free changeover contacts for each area
  • Released volt free contact per area
  • Fault volt free contact per area
  • Programmable extinguishant delays
  • Programmable output duration
  • Countdown indicator shows time until release in seconds
  • Mode select and manual release controls per area
  • Monitored remote manual release input
  • Monitored remote hold input
  • Monitored remote mode select (door interlock) input
  • Monitored remote released pressure switch input
  • Monitored Abort input
  • Serial connections for Sigma Si status units and ancillary boards. (K588)

 

 

 

Mô tả
Construction 1.2mm mild sheet steel
IP Rating IP30
Finish Epoxy powder coated
Colour - lid & box BS 00 A 05 grey - fine texture
Colour - controls plate & labels RAL 7047 light grey - satin
Weight 10kg
Mains supply 230V AC, 50Hz +10% - 15% (100 Watts maximum)
Mains supply fuse 1.6 Amp ( F1.6A L250V)
Power supply rating (1 & 2 area units) 3 Amps total including battery charge 28V +/- 2V
Power supply rating (3 & 4 area units) 4 Amps including battery charge 28V +/- 2V
Maximum ripple current 200 millivolts
Battery charge voltage 27.6VDC nominal (temperature compensated)
Battery charge current 0.7A maximum
Battery fuse 20mm, 3.15A glass
Current draw in mains fail condition 54 milliamps per extinguishing module
Max. current draw from batteries 3A (#31161M3, #32161M3, #31162M3, #32162M3)
5.25A (#31163M4, #32163M4, #31164M4, #32164M4)
Sigma XT+ module Aux 24V output Fused at 500mA with electronic fuse - 1 per extinguishant area
Syncro AS Aux 24V output Fused at 2.5A - not available to user
1st and 2nd stage Sounder outputs 21 to 28V DC Fused at 1A with electronic fuse
Fault relay contact rating 5 to 30VDC 1A Amp maximum for each
Fire relay contact rating 5 to 30VDC 1A Amp maximum for each
Local fire relay contact rating 5 to 30VDC 1A Amp maximum for each
First stage contact rating 5 to 30VDC 1A Amp maximum for each
Second stage contact rating 5 to 30VDC 1A Amp maximum for each
Extract contact rating 5 to 30VDC 1A Amp maximum for each
Terminal capacity 0.5mm2 to 2.5mm2 solid or stranded wire
Number of sounders per circuit Dependent on type and current consumption - typically 20+
Monitored input end of line 6K8 +/- 5% ½ Watt resistor
Sounder circuit end of line 10K +/- 5% ¼ Watt resistor
Extinguishant output end of line 1N4004 Diode
Number of detection loops 1 or 2
Number of zones 16
No. of sounder circuits Dependent on model 21 to 28V DC
Extinguishant release output 21 to 28V DC. Fused at 1 Amp
Download
Tên File Download
Datasheet › Việt Nam › English

Tin tức công ty

Tin công nghệ

Kinh nghiệm hay

Dịch Vụ

Giải pháp

Dự án

Tuyển dụng

Sản phẩm liên quan

Sigma A-Si

Sigma A-Si

Sigma A-Si Extinguishant Status Indicators

Sigma A-XT

Sigma A-XT

Sigma A-XT Extinguishant Control Panel

Syncro Si

Syncro Si

Syncro Si Analogue Addressable Extinguishant Status Units

Sigma XT Ancillaries

Sigma XT Ancillaries

Sigma XT Ancillaries

Sigma Si

Sigma Si

Sigma Si Extinguishant Status Indicators

Sigma XT+

Sigma XT+

Sigma XT+ Extinguishant Coincidence Unit

Sigma XT

Sigma XT

Sigma XT Extinguishant Control Panel

Công ty cổ phần Hệ Thống An Ninh Khai Phát (gọi tắt là Công ty KPS). GPDKKD: 0310471658 do sở KH & ĐT TP.HCM cấp ngày 24/11/2010. Đại diện pháp luật: Đinh Tấn Đạt.

2010 © Bản quyền thuộc KPS

Đang Online: 17 | Tổng Truy Cập: 9844061

Giới Thiệu | Tuyển dụng | Tin tức | Liên Hệ

zalo
messenger