KPS System Corp | Công ty cổ phần Hệ Thống An Ninh Khai Phát

Series 3000

Series 3000
  • The K3000 Series exceeds the requirements of BS5839: Part 4: 1988 in several areas. Inclusion of zone isolate, zonal one man test, zonal contacts, shop unit interface and zoned or two stage alarm outputs are all standard features.
  • A wide range of detectors are supported by the equipment, ensuring that the K3000 Series control panels can be used with existing installations without the need to change the field devices. Front panel controls and indicators are kept to a minimum to simplify user operation and to maintain clarity of indication. High intensity, twin bar LED indicators are used on all front panels. All panels are supplied with suitable power supply and generous battery space to give extended battery standby if required.
  • Ample cable entries and removable chassis assist in ease of installation. All panels are available as true flush or surface mounting and in two tone grey or cream and brown.
  • Other colours are available to special order. Arrangements can be made for special badging or special finishes such as brass or stainless steel.
  • K3000 Series control panels allow continued operation of call points and detectors upon removal of a device from the detection line. This can be achieved either by fitting an active end of line device or by using special line clamping bases.

 

 

Mô tả
Construction 1.2mm mild sheet steel
IP Rating IP30
Finish Epoxy powder coated
Standard colour BS 00 A 05 grey - fine texture
Sounder outputs 2 outputs each fused at 1 amp each (0.5A E3002001)
Isolatable fire contact Volt free changeover 1A at 30V DC
Auxiliary alarm contact Volt free changeover 1A at 30V DC
Fault contact Volt free changeover 1A at 30V DC
Zonal contacts Volt free normally open 1A at 30V DC
Auxiliary DC output Fused at 500mA
Detection zone monitoring resistor 6k8
Sounder circuit monitoring resistor 10k
Remote control inputs Alarm input, Silence input, Reset input
(option for pulsed alarm input [Security Alert])
Mains supply 230V AC (+10%/-15%)
(other voltages upon request)
Call points Require 470 OHM series resistor
Alarm threshold 100 to 900 Ohms
Short circuit threshold 0 to 100 Ohms
Maximum zone quiescent current 1.6mA
Active end of line K1406K (optional)
Operating temperature -5°C to +40°C
Operating humidity To 95% (non condensing)
Download
Tên File Download
Datasheet › Việt Nam › English

Tin tức công ty

Tin công nghệ

Kinh nghiệm hay

Dịch Vụ

Giải pháp

Dự án

Tuyển dụng

Sản phẩm liên quan

LCMU

LCMU

LCMU Line Continuity Monitoring Circuit

Sigma Matrix

Sigma Matrix

Sigma Matrix Conventional Fire Alarm Mimic System

Sigma CP Ancillaries

Sigma CP Ancillaries

Sigma CP Ancillaries Sigma CP Ancillary PCB

Sigma CP-R

Sigma CP-R

Sigma CP-R Conventional Fire Control Panel Repeaters

Sigma CP-A

Sigma CP-A

Sigma CP-A AlarmSense Compatible 2 Wire Conventional Fire Control Panels

Sigma CP

Sigma CP

Sigma CP Conventional Fire Control Panels

Công ty cổ phần Hệ Thống An Ninh Khai Phát (gọi tắt là Công ty KPS). GPDKKD: 0310471658 do sở KH & ĐT TP.HCM cấp ngày 24/11/2010. Đại diện pháp luật: Đinh Tấn Đạt.

2010 © Bản quyền thuộc KPS

Đang Online: 20 | Tổng Truy Cập: 9844239

Giới Thiệu | Tuyển dụng | Tin tức | Liên Hệ

zalo
messenger